Command classes
Configurations
Associations
Notification events
Product Identity
Central Scene
Multi-Command
Command classes
Command Class | Version | Required Security Class |
---|---|---|
APPLICATION STATUS | 1 | None |
ASSOCIATION | 2 | Highest granted Security Class |
ASSOCIATION GROUP INFO | 3 | Highest granted Security Class |
BATTERY | 1 | Highest granted Security Class |
CENTRAL SCENE | 3 | Highest granted Security Class |
CONFIGURATION | 4 | Highest granted Security Class |
DEVICE RESET LOCALLY | 1 | Highest granted Security Class |
FIRMWARE UPDATE MD | 5 | Highest granted Security Class |
INDICATOR | 3 | Highest granted Security Class |
MANUFACTURER SPECIFIC | 2 | Highest granted Security Class |
MULTI CHANNEL ASSOCIATION | 3 | Highest granted Security Class |
NOTIFICATION | 8 | Highest granted Security Class |
POWERLEVEL | 1 | Highest granted Security Class |
SECURITY 2 | 1 | None |
SENSOR MULTILEVEL | 11 | Highest granted Security Class |
SUPERVISION | 1 | None |
TRANSPORT SERVICE | 2 | None |
VERSION | 3 | Highest granted Security Class |
WAKE UP | 2 | Highest granted Security Class |
ZWAVEPLUS INFO | 2 | None |
Configurations
No. | Name | Description | Size | Values | Default value | Advance configuration |
---|---|---|---|---|---|---|
LED | ||||||
2 | LED alarm event reporting | Turn On or Off LED for specific event indications (ex. alarms) | 1 byte | 0: Off | 1 | No |
1: On, but no LED indication for associated nodes (1/5 blinks) | ||||||
2: On with LED indications based on success/fail for BOTH the gateway and the associated nodes | ||||||
Temperature & Humidity reporting | ||||||
4 | Temperature & Humidity reporting | Select temperature and humidity reporting | 1 byte | 0: Off | 1 | No |
1: On. Sends temperature/humidity based on difference from last reported value (set in config parameters 26 and 28) | ||||||
2: On. Timed reporting of the actual temperature and the actual humidity value (set time in config parameter 25) | ||||||
3: On. Timed reporting of the average temperature value between reports. Will also send the actual humidity value (set time in config parameter 25) | ||||||
5 | Temperature unit | Select the temperature unit | 1 byte | 0: Celcius | 0 (Except US frequency) 1 (US frequency) | No |
1: Fahrenheit | ||||||
6 | Temperature alarms | Turn On or Off temperature alarm (The alarms are not affected by parameters 4, 25 or 26) | 1 byte | 0: Off | 0 (Off) | No |
1: On | ||||||
7 | High temperature alarm level | Select high temperature alarm level | 2 bytes | -20 to +80 (degree C) -4 to +176 (degree F) | 40 C or 104 F (US frequency) | No |
8 | Low temperature alarm level | Select low temperature alarm level | 2 bytes | -20 to +60 (degree C) -4 to +140 (degree F) | 5 C or 41 F (US frequency) | No |
25 | Temperature and Humidity reporting time (Activated in config parameter 4) | Select the number of minutes between reports (15 mins to 24 hrs) | 2 bytes | 15-1440: Minutes between reports (periodic reporting) | 60 | No |
26 | Temperature change for next report (Activated in config parameter 4) | Temperature must change by this value for a new report | 1 byte | 5 – 100 Input value converted to one decimal place [= 0.5 to 10.0 (degree C/F)] | 20 ( = 2.0 C) or 30 ( = 3 F) (US frequency) | No |
28 | Humidity change for next report (Activated in config parameter 4) | Humidity must change by this value for a new report | 1 byte | 2 to 10 (%) | 5 (%) | No |
Ambient Light | ||||||
9 | Ambient light reporting | Ambient light report settings. Using a filter (low-pass) is highly recommended to avoid large amounts of reports in fluctuating lights. | 1 byte | 0: Off | 8 | No |
1: Reporting visual changes without filter (This configuration will affect the sensor battery life if placed where light fluctuates significantly) | ||||||
2-8: Filter length. 2 is the fastest filter allowing quick responses. 8 is a slower filter setting and will give the longest battery life | ||||||
10 | High ambient light (LUX) level trigger | The sensor will send a light report when the light rises above this level. Can be used in scenarios to trigger other devices. When enabling parameter 10, parameter 11 must also be set with a lower value, else the trigger stays off | 4 bytes | 20 – 64000 (LUX) 0: Off | 0 (Off) | No |
11 | Low ambient light (LUX) level trigger | The sensor will send a light report when the light goes below this level. Can be used in scenarios to trigger other devices. When enabling parameter 11, parameter 10 must also be set with a greater value, else the trigger stays off | 4 bytes | 10 – 42000 (LUX) 0: Off | 0 (Off) | No |
Slider switch | ||||||
29 | Slider switch function | Select if the switch should act as a binary switch or a timed switch | 1 byte | 1. Binary switch | 1 | Yes |
2. Timed switch | ||||||
30 | Timed switch duration | Select the duration that should trigger the opposite state of the switch (if 2 is selected in config parameter 29) | 1 byte | 1-60 (minutes) | 5 | Yes |
Z-Wave Command Class | ||||||
31 | Use Multi-Command encapsulation | Send Temperature and Humidity sensor value reports and or Temperature Alarms related reports (Notification Report + Multi-Level Sensor Report + Central Scene Notification) in one message, this saves battery power. Make sure your gateway supports Multi-Command Command Class first | 1 byte | 0: Off | 0 (Off) | Yes |
1: On | ||||||
32 | Use Central Scene Notifications | Central Scene Notifications are sent for the Slider switch state change, High and Low Temperature Alarms and High and Low Ambient Light states. Scenes could be configured in the gateway. Scenes allow multiple devices to be controlled by a single Z-Wave command | 1 byte | 0: Off | 1 (On) | Yes |
1: On | ||||||
Associations | ||||||
33 | Basic Set value sent to Association group 3 when the slider switch is on | This config parameter defines the value sent to the devices in the Association group 3 (using Basic Command Class) | 1 byte | 0 – 255 | 255 | Yes |
34 | Basic Set value sent to Association group 3 when the slider switch is off | This config parameter defines the value sent to the devices in the Association group 3 (using Basic Command Class) | 1 byte | 0 – 255 | 0 | Yes |
35 | Thermostat mode for Association group 4 when the slider switch is on | This config parameter defines the value sent to the devices in the Association group 4 (using Thermostat Mode Command Class). Refer the Thermostat modes supported by the associated node | 1 byte | 1 – 13 | 1 | Yes |
36 | Basic Set value sent to Association group 6 on High Temperature Alarm | This config parameter defines the value sent to the devices in the Association group 6 (using Basic Command Class) | 1 byte | 0 – 255 | 0 | Yes |
37 | Basic Set value sent to Association group 6 on Low Temperature Alarm | This config parameter defines the value sent to the devices in the Association group 6 (using Basic Command Class) | 1 byte | 0 – 255 | 255 | Yes |
38 | Basic Set value sent to the Association group 7 on High ambient light level report | This config parameter defines the value sent to the devices in the Association group 7 (using Basic Command Class) | 1 byte | 0 – 255 | 255 | Yes |
39 | Basic Set value sent to the Association group 7 on Low ambient light level report | This config parameter defines the value sent to the devices in the Association group 7 (using Basic Command Class) | 1 byte | 0 – 255 | 0 | Yes |
Associations
Group | Name | Maximum no. of devices | Commands | Information |
---|---|---|---|---|
1 | Lifeline | 1 | Notification Report | |
Battery Report | ||||
Multilevel Sensor Report | ||||
Central Scene Notification | ||||
Device Reset Locally Notification | ||||
Indicator Report | ||||
Multi-Command Encapsulation Command | ||||
Slider Switch | ||||
2 | Binary Switch | 5 | Binary Switch Set | OFF – 00 (0x00) ON – 255 (0xFF) This association shall work for both Binary Switch and Timed Switch functions set in configuration parameter 29 – Slider switch function |
3 | Basic Set for Binary Switch | 5 | Basic Set | OFF – 00 (0x00) ON – 255 (0xFF) Values could be modified using the configuration parameters 33 & 34 This association shall work for both Binary Switch and Timed Switch functions set in configuration parameter 29 – Slider switch function |
4 | Thermostat Mode Set for Binary Switch | 5 | Thermostat Mode Set | Pre-requisite: configuration parameter no. 29 – Slider switch function set to 1 (Binary Switch) OFF – 00 (0x00) or The value set in the configuration parameter 35, Default is Heat Mode On – 01 (0x01) |
Temperature Alarms | ||||
5 | Temperature Report for Temperature Alarms | 5 | Multilevel Sensor Report | Temperature Value |
6 | Basic Set for Temperature Alarms | 5 | Basic Set | High temperature alarm = OFF – 00 (0x00) Low temperature alarm = ON – 255 (0xFF) Values could be modified using the configuration parameters 36 & 37 |
Ambient light (LUX) level trigger | ||||
7 | Basic Set for Ambient Light Report Levels | 5 | Basic Set | High ambient light (LUX) level trigger = ON – 255 (0xFF) Low ambient light (LUX) level trigger = OFF – 00 (0x00) Values could be modified using the configuration parameters 38 & 39 |
Notification events
Notification Type | Notification Event | Information |
---|---|---|
Heat Alarm (04) | Clear Notification (00) | When other 2 events below are cleared |
Overheat detected (02) | Strips will send Heat Alarm when temperature rises above the set value in configuration parameter no.7 | |
Under heat detected (06) | Strips will send Heat Alarm when temperature falls below the set value in configuration parameter no.8 | |
Home Security (07) | Clear Notification (00) | When other event (11) is cleared |
Magnetic Field Interference Detected Event (11) | Strips will send a tamper alert if it detects that someone tries to wake up or manipulate Strips. |
Product Identity
Indicator ID | Description | Appearance and use |
---|---|---|
80 (0x50) | Node Identify | The LED indicator is used to identify the node. |
Central Scene
Event | Scene | Key attribute |
---|---|---|
Slider Switch | ||
Slider switch on | Scene 1 | Key Pressed (00) |
Slider switch off | Scene 2 | Key Pressed (00) |
Ambient light (LUX) level trigger | ||
High ambient light (LUX) level trigger | Scene 3 | Key Pressed (00) |
Low ambient light (LUX) level trigger | Scene 4 | Key Pressed (00) |
Temperature Alarms | ||
High Temperature Alarm | Scene 5 | Key Pressed (00) |
Low Temperature Alarm | Scene 6 | Key Pressed (00) |
Multi-Command
Scenarios | Commands encapsulated in MultiCmd command |
---|---|
Temperature + Humidity levels Reporting | MultiLevel Sensor Report (Temperature) + MultiLevel Sensor Report (Humidity) |
Temperature Alarms (High\Low) | Central Scene Notification (Scene 5\6) + MultiLevel Sensor Report (Temperature) + Notification (Alarm) Report (High\Low Temperature Alarm) |
Temperature Alarms Clear (High\Low) | MultiLevel Sensor Report (Temperature) + Notification (Alarm) Clear Report (High\Low Temperature Alarm) |